Fire NOC in Mumbai 19 min read

Fire NOC consultants in Mumbai: who issues your fire NOC, where to file and what it costs

Updated By Flamekite Editorial DeskFacts checked against official sources on

Fire NOC in Mumbai: MCGM's Chief Fire Officer or MIDC, autoDCR filing in 7 and 15 working days, 2026-27 trade fees from ₹8,070, and the 2025-26 drives.

Building fire NOC (autoDCR)
7 working days
Occupation NOC: 15 working days
The three NOCs 
Trade NOC under section 394
10 working days
1 + 7 + 2 days on the DFO console
Trade NOC route 
Trade compliance fee, up to 50 m²
₹8,070
MCGM schedule for 2026-27
Mumbai fees 
Mumbai Fire Brigade stations
34
Per its RTI manual; 6 commands
The numbers 

Quick answer

In Mumbai the fire NOC is issued by the Chief Fire Officer of the Mumbai Fire Brigade, MCGM's fire department, under the Maharashtra Fire Prevention and Life Safety Measures Act, 2006; a plot inside an MIDC industrial area goes to MIDC's own fire service instead.

For a new building your architect applies through the Common Application Form on MCGM's autoDCR single window, where the Right to Service limit is 7 working days for the building NOC and 15 for the occupation NOC. A shop, eatery or clinic gets its own trade NOC under section 394 of the MMC Act on the MCGM portal, a 10-working-day process.

Mumbai fire NOC at a glance

Who decides, where you file and how long it takes in Mumbai, with the source of each fact.
WhatThe ruleSource
Issuing officer, MCGM limitsChief Fire Officer, Mumbai Fire Brigade (Byculla Command Centre, B. J. Marg, Byculla West)MCGM auditor 2021
Issuing officer, MIDC areasMIDC's fire service, through the Divisional Fire Officer of the MIDC regionMIDC EoDB
The lawMaharashtra Fire Prevention and Life Safety Measures Act, 2006, with the 2023 amendment in force from 30 May 2023UDD notification 2023
MCGM's fire dutyObligatory under section 61(k) of the Mumbai Municipal Corporation ActMFB RTI manual
Building and occupation NOC portalautoDCR Online Building Plan Approval System, through the Single Window Clearance System's Common Application FormMCGM autoDCR FAQ
Trade NOC portalMCGM portal, section 394 of the MMC Act, routed to 11 DFO consoles by wardMumbai Fire Brigade
Right to Service limits7 working days for a building fire NOC (fresh or revised), 15 working days for the fire occupation NOCMCGM autoDCR FAQ
Low-rise splitResidential buildings up to 32 m follow MCGM's codified requirementsMumbai Fire Brigade
After occupationForm B from a licensed agency every January and July, filed with the Mumbai Fire BrigadeFree Press Journalnews report

Mumbai's three fire NOCs: building, occupation and trade

The three fire NOCs a Mumbai owner meets, compared stage by stage.
OptionBuilding NOC (plan stage)Occupation NOCTrade NOC (section 394)Source
Who appliesThe architect or licensed surveyorThe architect, before the occupation certificateThe trader or occupierMCGM autoDCR FAQ
WhereautoDCR, Common Application FormautoDCR, Common Application FormMCGM portal, DFO console of the wardMumbai Fire Brigade
Right to Service or SOP time7 working days15 working days10 working days (1 assign, 7 inspect, 2 issue)MCGM autoDCR FAQ
Site inspectionNone for fresh or revised plansYesYes, against a checklistMumbai Fire Brigade
Key papersCTS number, ward, height, gross built-up area certificate, 3 plan setsEarlier NOCs, IOD or CC, structural stability, Form A, PWD lift certificates at 24 m or moreIndemnity bond on ₹500 stamp paper with the trade documentsMumbai Fire Brigade
Fee basis (2026-27)Scrutiny at 10% of the Fire Service and Emergency feePer MCGM's schedule₹8,070 to ₹64,430 by floor areaMCGM BRC 69

How to get a fire NOC for a new Mumbai building

  1. Confirm the plot's fire authority

    Inside MCGM's 24 administrative wards the Mumbai Fire Brigade decides. A plot in an MIDC industrial area, such as the Marol estate in Andheri East, goes to MIDC's fire service and its single window.

  2. File the CFO NOC with the building proposal

    The architect applies on autoDCR through the Common Application Form, with the CTS number, ward, height to the terrace slab, the gross built-up area certificate and 3 plan sets. No separate application to the fire department is needed.

  3. Receive the building NOC

    The Right to Service limit for a fresh or revised building fire NOC is 7 working days. The fire brigade does not inspect the site at plan stage.

  4. Build to the NOC and keep revisions minor

    A minor amendment that leaves open spaces, refuge floors, exits and travel distance unchanged needs no revised CFO NOC at intermediate stages; the change is checked at the occupation NOC.

  5. Install through a licensed agency

    A Maharashtra-licensed agency installs the fire systems and issues Form A, which the Mumbai Fire Brigade asks for with its annexure at the occupation stage.

  6. Apply for the fire occupation NOC

    The fire brigade inspects the building. Attach earlier NOCs, the IOD or CC, a structural stability certificate and, at 24 m or more, the PWD lift certificates. The Right to Service limit is 15 working days.

  7. Start the Form B calendar

    Once occupied, the building files Form B from a licensed agency every January and July with the Mumbai Fire Brigade.

Who issues the fire NOC at your Mumbai address?

Mumbai has one municipal fire service, but not every plot answers to it. Start with where the plot sits.

  1. IfThe plot is in any of MCGM's 24 wards, from A ward (Colaba, Fort) to T ward (Mulund)

    The Mumbai Fire Brigade's Chief Fire Officer issues building and occupation NOCs, and the ward's DFO console handles trade NOCs. Mumbai Fire Brigade

  2. IfThe plot is in an MIDC industrial area, such as the Marol estate around MIDC's Andheri East headquarters

    MIDC's fire service issues the Provisional and Final Fire Approval through the MIDC single window; MIDC runs a fire station at SEEPZ Gate No. 1, Andheri. MIDC fire stations

  3. IfIt is a warehouse on a plot below 900 m² inside MCGM limits

    No CFO NOC is needed for construction; the architect, owner or occupant self-certifies compliance. Warehouses MCGM autoDCR FAQ

  4. IfIt is a shop, eatery, clinic or other licensed trade inside an existing Mumbai building

    Besides the building's own approvals, the trade needs a fire NOC under section 394 of the MMC Act, filed on the MCGM portal. Fire NOC for Shop Mumbai Fire Brigade

  5. IfThe address is in Thane, Navi Mumbai, Mira-Bhayandar or Vasai-Virar rather than Mumbai

    That city's own municipal Chief Fire Officer decides; the Mumbai Fire Brigade has no NOC role there. Fire NOC Maharashtra Amendment Act 2023

Mumbai fire NOC lines by height: 24 m, 32 m, 70 m and 90 m

The height of a Mumbai building, measured to the terrace slab, moves it between fee classes, document lists and audit duties.

What changes in MumbaiStage it bites
Up to 32 m, residential Mumbai Fire BrigadeMCGM's codified low-rise list: 4.5 m gate and archway clearance, courtyards paved for 28-tonne fire engines, sprinklers across the whole car parkPlan and occupation
24 m and above Mumbai Fire BrigadePWD lift certificates join the occupation NOC fileOccupation
Above 32 m MCGM BRC 69The high-rise class in MCGM's 2026-27 fee schedule; scrutiny still 10% of the base feePlan
45 m and above, residential Mumbai Fire BrigadeNamed first among the Mumbai Fire Brigade's priority Form B filersAfter occupation
Above 70 m, residential Amendment Act 2023A section 45 building: automated monitoring system and a licensed fire audit every 2 yearsAfter occupation
Every high-rise (2024 notification, as reported) Free Press Journalnews reportA fire tower of 2-hour resistance with a fireman evacuation lift and ventilated lobbyPlan
90 m and above (as reported) Free Press Journalnews reportA fire break water tank with pumps at every 65 m of heightPlan
Over 10,000 m² built-up or over 1,000 occupants (as reported) Free Press Journalnews reportVulnerable-building provisions by risk score, added to DCPR 2034 for Greater MumbaiPlan

The 2024 rows come from the Free Press Journal's report of 12 October 2024 on the Urban Development Department's notifications; Flamekite has not read the notifications themselves.

What does a fire NOC cost in Mumbai in 2026-27?

MCGM publishes its fire fees as a yearly schedule; the 2026-27 one is BRC No. 69 of 30 March 2026.

As published

  • Building scrutiny, low-rise up to 32 m or high-rise above 32 m10% of the Fire Service and Emergency feeBase fee per BRC 78 of 15.03.2024 MCGM BRC 69
  • Internal alteration or change of user in an existing building₹25,000 or the per-m² figure, whichever is higher MCGM BRC 69
  • Trade compliance, up to 50 m²₹8,070₹7,330 in 2025-26 MCGM BRC 69
  • Trade compliance, 50 to 100 m²₹16,120 MCGM BRC 69
  • Trade compliance, 100 to 200 m²₹32,320 MCGM BRC 69
  • Trade compliance, above 200 m²₹64,430₹58,570 in 2025-26 MCGM BRC 69
  • Compliance scrutiny when a trade licence is renewed₹4,050 to ₹32,220 MCGM BRC 69
  • Undertaking-cum-indemnity bond with a trade NOC₹500 stamp paper Mumbai Fire Brigade
  • MIDC plot, Provisional Fire ApprovalFire Protection Fund fee on an online demand noteRate not published on the EoDB page MIDC EoDB

These are MCGM's own charges. A consultant's or licensed agency's fee is separate and is not set by MCGM. The per-m² formula behind the Fire Service and Emergency fee is not published in the copy Flamekite read.

Where do you apply for a Mumbai fire NOC online?

Mumbai has no stand-alone fire portal: the NOC rides on the building, trade or MIDC application.

How a Mumbai trade fire NOC moves in 10 working days

MCGM's standard operating procedure for section 394 NOCs sets every hand-off and its time.

  1. Console by ward

    The online application lands on 1 of 11 DFO consoles: for example RCC-1-A for A, B and C wards, RCC-3-A for H/E, H/W, K/E and K/W, and RCC-6-A for N, S and T. Mumbai Fire Brigade

  2. Day 1: assignment

    The Divisional Fire Officer assigns the file to a designated officer within 1 working day. Mumbai Fire Brigade

  3. Days 2 to 8: inspection

    The designated officer inspects against the checklist and prepares the NOC within 7 working days. Mumbai Fire Brigade

  4. Days 9 and 10: issue

    The officer of the rank the risk tier sets issues the NOC within 2 working days. Mumbai Fire Brigade

Which Mumbai fire officer signs your trade NOC?

Floor area or LPG cylinders, whichever is higher, set the rank that issues a Mumbai trade NOC.

Below 50 m², or 1 or 2 LPG cylinders
Station Officer or Senior Station Officer inspects and issues. Mumbai Fire Brigade
50 to 500 m², or 3 to 10 cylinders
Station Officer inspects; Assistant Divisional Fire Officer issues. Mumbai Fire Brigade
Above 500 m², or 11 to 20 cylinders
Assistant Divisional Fire Officer inspects; Divisional Fire Officer issues. Mumbai Fire Brigade
More than 20 cylinders
Assistant Divisional Fire Officer inspects; Deputy Chief Fire Officer issues. Mumbai Fire Brigade

Mumbai fire offices that handle NOCs, with published numbers

Only offices and numbers the fire services publish themselves, read on 28 October 2026.

  • Chief Fire Officer, Mumbai Fire Brigade MCGM auditor 2021

    Building and occupation NOCs within MCGM limits; Form B

    Address
    Byculla Command Centre, B. J. Marg, Byculla (West), Mumbai 400008
  • Mumbai Fire Brigade regional commands MFB RTI manual

    6 Deputy CFO commands at Byculla, Wadala, Marol, Borivali, Mankhurd and Vikhroli; city headquarters Byculla, suburban headquarters Marol

  • Regional DFOs and Deputy CFOs (RTI) Mumbai Fire Brigade

    6 regional DFOs are Public Information Officers and 6 regional Deputy CFOs the appellate officers, at addresses of the form dfoNN.mfb@mcgm.gov.in

  • MIDC Fire Station, SEEPZ MIDC fire stations

    MIDC fire station in Mumbai Suburban district

    Address
    Plot No. A-1, SEEPZ Gate No. 1, near Suncity Hotel, Andheri, Mumbai 400096
  • MIDC fire office, headquarters MIDC fire stations

    MIDC's fire headquarters (fohq@midcindia.org)

    Address
    Udyog Sarathi, Mahakali Caves Road, Marol Industrial Area, Andheri (East), Mumbai 400093
  • Directorate of Maharashtra Fire and Emergency Services MFS

    Agency and auditor licences; approvals outside CFO areas

    Address
    Hans Bhugra Marg, Kalina, Santacruz (East), Mumbai 400098

The Mumbai Fire Brigade in numbers

The size of the service that inspects Mumbai buildings, and of its latest drive.

What Mumbai has been enforcing in 2025 and 2026

From news reports, not yet an official source.

Newspaper reports of the Mumbai Fire Brigade's and the state's actions, dated and labelled.

Reported in the press; Flamekite has not seen the underlying orders.

  • A state decision under section 3 of the Maharashtra Right to Services Act, 2015 cut the fire services NOC time in municipal corporations and councils from 15 days to 12. Free Press Journalnews report

  • The Mumbai Fire Brigade inspected 2,703 establishments from 22 to 30 December, including 1,993 restaurants, 325 pubs, bars and clubs, 194 lodging houses, 51 five-star hotels, 38 malls and 37 rooftop venues; it acted against 136 and served notices on 55. Free Press Journalnews report

  • A night operation at Kamala Mills and Shakti Mills, Lower Parel, covered 15 establishments and seized 8 commercial LPG cylinders and 200 kg of charcoal. Free Press Journalnews report

  • After a hotel fire in Delhi that killed 21, BMC and the fire brigade ran a joint drive from 6 to 20 June; kitchens built on open spaces at 5 Andheri (West) venues were demolished and 17 commercial LPG cylinders seized. Free Press Journalnews report

  • BMC cut the time to fix fire safety defects from up to 120 days to between 15 days and 1 month, with electricity and water at risk; 428 hotels, restaurants, bars and banquet halls had been inspected since January. Mumbaikar Newsnews report

  • The state told its Legislative Council that 68 Mumbai malls had been inspected after the Rajkot game-zone fire: 47 adequate, 18 given 120-day notices and 3 still closed. Free Press Journalnews report

Mumbai fires and rule changes, 1887 to 2024

The fires that shaped how Mumbai inspects buildings, and the rules that followed.

  1. 1 April 1887

    Fire protection in Bombay passes from the police to the Municipality as a full-time subject. MFB RTI manual

  2. 29 December 2017

    The Kamala Mills fire at the 1Above rooftop bar and Mojo's Bistro, Lower Parel, kills 14. Wikipedianews report

  3. 26 March 2021

    A fire in Dreams mall, Bhandup, reaches the hospital on its top floor; the toll is put at 10, and the mall had a fire notice from November 2020. TBS Newsnews report

  4. 25 August 2021

    MCGM invites Fire and Life Safety Auditors to certify NOC compliance of residential buildings up to 32 m, for a ₹5,000 empanelment fee. MCGM auditor 2021

  5. 22 January 2022

    A fire in the 20-storey Kamala building, Tardeo, leaves at least 6 dead and 15 injured. Scroll.innews report

  6. 30 May 2023

    Maharashtra's 2023 Amendment Act comes into force: Provisional, Final and Renewal approvals, and the 2-yearly section 45A audit. UDD notification 2023

  7. October 2024

    After a Bombay High Court PIL, the Urban Development Department notifies fire provisions for vulnerable buildings into DCPR 2034, as reported on 12 October. Free Press Journalnews report

Mumbai buildings that need fire NOCs most often

Each type has its own all-India page; here is the Mumbai detail that changes the file.

Five Mumbai buildings and what the rules make each do

Real-shaped cases worked from MCGM's and MIDC's published rules. They are examples, not client stories.

  1. Case 1

    A 30 m residential building in Borivali

    New G+9 housing, about 30 m to the terrace slab, R/C ward.

    What applies Below 32 m, so MCGM's codified low-rise list applies: 4.5 m gate clearance, a courtyard paved for 28-tonne engines and car-park sprinklers. At 24 m or more the occupation NOC also needs the PWD lift certificates. Mumbai Fire Brigade

  2. Case 2

    A 600 m² restaurant-bar in Lower Parel

    G/S ward, 12 commercial LPG cylinders.

    What applies Above 500 m² and 11 to 20 cylinders: an ADFO inspects and the Divisional Fire Officer issues the trade NOC from console RCC-2-B. The 2026-27 trade compliance fee above 200 m² is ₹64,430. Mumbai Fire Brigade

  3. Case 3

    A storage shed on an 850 m² plot in Kurla

    Warehouse, plot below 900 m², inside MCGM limits.

    What applies No CFO NOC for construction; the architect, owner or occupant self-certifies fire compliance with the building proposal. MCGM autoDCR FAQ

  4. Case 4

    A new unit on an MIDC plot in Marol

    Light-engineering building in the Marol MIDC estate, Andheri East.

    What applies MIDC's fire service, not the Mumbai Fire Brigade: Provisional Fire Approval through the MIDC single window within 30 days of a complete file, Final Fire Approval in 15, and Form B online on the MIDC portal. MIDC EoDB

  5. Case 5

    A 10-bed nursing home in Dadar

    Registered with MCGM's Health Department, on the first floor of a mixed building.

    What applies Fire compliance under section 394 with MCGM's document list, including an electrical audit, Form A and Form B and an indemnity bond on ₹500 stamp paper. Mumbai Fire Brigade

Form B, audits and renewals for Mumbai buildings

Maharashtra fixes no general renewal period; the Mumbai duties after occupation are filings.

Do

  • File Form B from a licensed agency with the Mumbai Fire Brigade every January and July. Free Press Journalnews report
  • For a residential tower above 70 m, book a licensed Fire and Life Safety Auditor every 2 years. Amendment Act 2023
  • On an MIDC plot, file Form B online on the MIDC portal, as required since 1 January 2025. MIDC circular
  • When a Mumbai trade licence is renewed, budget for the ₹4,050 to ₹32,220 compliance scrutiny fee. MCGM BRC 69

Don’t

  • Don't wait for a renewal date on the NOC: the 2023 amendment issues a renewal only where another Act or rule requires one. Amendment Act 2023
  • Don't use MCGM's 2021 empanelled auditor for a section 45A audit: that route certifies NOCs for residential buildings up to 32 m. MCGM auditor 2021
  • Don't treat a 120-day notice period as normal: since June 2026 BMC gives 15 days to 1 month. Mumbaikar Newsnews report

Mumbai fire NOC mistakes that cost weeks

Problems Flamekite sees when MCGM's published rules are read against how files are actually prepared.

  • If A plan revision moves a staircase or a refuge floor

    Only minor amendments that keep open spaces, refuge floors, exits and travel distance unchanged skip a revised CFO NOC; anything else needs a fresh 7-working-day NOC. MCGM autoDCR FAQ

  • If A restaurant adds cylinders after its NOC

    Crossing 2, 10 or 20 cylinders moves the NOC to a higher officer; declare the real count before an inspection finds it. Mumbai Fire Brigade

  • If A kitchen or store is built on the compulsory open space

    In June 2026 such kitchens at 5 Andheri (West) venues were demolished. Keep open spaces clear for fire engines. Free Press Journalnews report

  • If The small-warehouse exemption is read as no fire duty at all

    Below 900 m² of plot only the construction NOC is waived; compliance is still self-certified and the trade still needs its section 394 NOC. MCGM autoDCR FAQ

  • If An MIDC plot is filed with MCGM

    Plots in MIDC areas go to MIDC's Divisional Fire Officer through the MIDC single window. MIDC EoDB

What Flamekite does for a fire NOC in Mumbai

The service, stated plainly. The Mumbai Fire Brigade or MIDC decides every application.

  • A free first check: which of the 3 Mumbai NOCs your building or trade needs, and whether MCGM or MIDC decides. Mumbai Fire Brigade
  • The CFO file your architect submits on autoDCR's Common Application Form, and follow-up against the 7 and 15 working-day limits. MCGM autoDCR FAQ
  • Section 394 trade NOC filing on the MCGM portal, with the floor area and LPG count declared correctly for the right officer tier. Mumbai Fire Brigade
  • Installation, Form A and the January and July Form B by Maharashtra-licensed partners working under Flamekite's supervision. MFS Form B guidelines
  • Section 45A audits for towers above 70 m through a licensed Fire and Life Safety Auditor. Amendment Act 2023

What Flamekite could not confirm about Mumbai fire NOCs

These gaps were open on 28 October 2026. Where a Mumbai file depends on one of them, ask the fire officer in writing.

  • The per-m² formula behind MCGM's Fire Service and Emergency fee under BRC 78 of 15 March 2024.
  • The text of the fire provisions in DCPR 2034 and the numbers of the October 2024 notifications; the rows above rest on a newspaper report.
  • Whether buildings in MMRDA's Bandra Kurla Complex take their fire NOC from the Mumbai Fire Brigade or another officer.
  • Whether MCGM's 7-working-day and 15-working-day autoDCR limits were shortened by the state's June 2025 decision of 12 days for fire NOCs.
  • A current station-wise phone list for the Mumbai Fire Brigade; the RTI manual giving 34 stations is undated, and press reports give 33 to 35.
  • Whether a unit inside the SEEPZ special economic zone takes its fire NOC from MIDC's SEEPZ fire station.

Questions about Mumbai

Who issues the fire NOC in Mumbai?

The Chief Fire Officer of the Mumbai Fire Brigade, MCGM's fire department, issues fire NOCs for buildings inside MCGM's 24 wards under the Maharashtra Fire Prevention and Life Safety Measures Act, 2006. Plots in MIDC industrial areas, such as the Marol estate in Andheri East, get their fire approval from MIDC's own fire service.

How long does a fire NOC take in Mumbai?

MCGM's autoDCR system gives 7 working days under Right to Service for a fresh or revised building fire NOC and 15 working days for the fire occupation NOC. A trade NOC under section 394 of the MMC Act runs 10 working days: 1 to assign, 7 to inspect and draft, 2 to issue.

What is the fire NOC fee in Mumbai?

Under MCGM's 2026-27 schedule, trade compliance costs ₹8,070 up to 50 m², ₹16,120 for 50 to 100 m², ₹32,320 for 100 to 200 m² and ₹64,430 above 200 m². Building scrutiny is 10% of the Fire Service and Emergency fee, and an alteration or change of user is at least ₹25,000.

Can I apply for a Mumbai fire NOC online?

Yes. Building and occupation fire NOCs are filed on MCGM's autoDCR system through the Single Window Clearance System's Common Application Form, trade NOCs on the MCGM portal, and MIDC fire approvals and Form B on the MIDC services portal.

Does a shop or restaurant in Mumbai need its own fire NOC?

Yes. A trade licensed under section 394 of the MMC Act needs its own fire NOC from the Mumbai Fire Brigade, separate from the building's approvals. Floor area and LPG cylinders set the officer: above 20 cylinders a Deputy Chief Fire Officer issues it.

Does a Mumbai fire NOC need renewal?

Maharashtra's Act fixes no general renewal period. Instead, a licensed agency's Form B is filed with the Mumbai Fire Brigade every January and July, and residential towers above 70 m need a licensed fire audit every 2 years.

What are the fire rules for high-rise buildings in Mumbai?

Residential buildings up to 32 m follow MCGM's codified low-rise list, buildings of 24 m or more add PWD lift certificates at occupation, and towers above 70 m are section 45 buildings with a 2-yearly audit. Notifications reported in October 2024 add a 2-hour fire tower to every high-rise and break tanks every 65 m at 90 m and above.

Does a small warehouse in Mumbai need a fire NOC?

Not for construction if the plot is below 900 m² and inside MCGM limits: the architect, owner or occupant self-certifies fire compliance instead. A trade run from the warehouse still needs its section 394 fire NOC.

Keep reading

Free tools for this

Words on this page, explained

Sources

Each source was opened and read on the date shown. How Flamekite checks its sources

  1. Government of Maharashtra (copy hosted by PRS Legislative Research): Maharashtra Fire Prevention and Life Safety Measures Act, 2006 (Mah. Act No. III of 2007) (opens in a new tab)checked 24 October 2026
  2. Government of Maharashtra (copy hosted by Maharashtra Fire and Emergency Services): Maharashtra Fire Prevention and Life Safety Measures (Amendment) Act, 2023 (Mah. Act No. XXIV of 2023), first published 11 May 2023 (opens in a new tab)checked 25 October 2026
  3. Urban Development Department, Government of Maharashtra (gazette copy hosted by MFS): Notification No. FFS-2022/C.R.36/UD-14, 30 May 2023: the Maharashtra Fire Prevention and Life Safety Measures (Amendment) Act, 2023 comes into force on 30 May 2023 (Gazette Extraordinary Part IV-B No. 209) (opens in a new tab)checked 25 October 2026
  4. Municipal Corporation of Greater Mumbai, Chief Fire Officer: RTI Manual No. 1: particulars of organisation, set-up and history of the Mumbai Fire Brigade (34 fire stations, 6 commands; undated) (opens in a new tab)checked 28 October 2026
  5. Municipal Corporation of Greater Mumbai, Building Proposal Department: Online Building Plan Approval System, FAQ: CFO NOC through the Single Window Clearance System, 7 and 15 working days, warehouses below 900 m² plot (opens in a new tab)checked 28 October 2026
  6. Maharashtra Industrial Development Corporation: Fire Department: duties under the 2006 Act and MIDC's Development Control Rules (page updated 9 March 2026) (opens in a new tab)checked 28 October 2026
Show all 34 sourcesShow fewer
  1. Maharashtra Industrial Development Corporation: Fire services: 32 fire stations operational and 14 sanctioned (page updated 9 March 2026) (opens in a new tab)checked 28 October 2026
  2. Municipal Corporation of Greater Mumbai, Mumbai Fire Brigade: Fire SOP, single window: online trade NOC under section 394 of the MMC Act (opens in a new tab)checked 28 October 2026
  3. Municipal Corporation of Greater Mumbai, Mumbai Fire Brigade: List of documents: proposals (fresh or revised building plans) (opens in a new tab)checked 24 October 2026
  4. Municipal Corporation of Greater Mumbai, Mumbai Fire Brigade: List of documents: occupation-stage fire NOC (opens in a new tab)checked 24 October 2026
  5. Municipal Corporation of Greater Mumbai, Mumbai Fire Brigade: Advertisement and terms, 25 August 2021: empanelment of Fire and Life Safety Auditors for the NOC of residential buildings up to 32 m (Rs 5,000 fee, Rs 2,500 yearly renewal) (opens in a new tab)checked 25 October 2026
  6. Maharashtra Industrial Development Corporation: Fire NOC procedure on the MIDC Ease of Doing Business pages: an existing factory attaches its Form B with Annexure; applications go to the regional Divisional Fire Officer (opens in a new tab)checked 28 October 2026
  7. Municipal Corporation of Greater Mumbai, Mumbai Fire Brigade: Codified requirements for low-rise residential buildings (up to 32 m) (opens in a new tab)checked 24 October 2026
  8. Maharashtra Industrial Development Corporation: Contact details of MIDC fire stations: 39 rows by region, with addresses, phones and e-mail (PDF uploaded September 2021) (opens in a new tab)checked 28 October 2026
  9. Municipal Corporation of Greater Mumbai, Mumbai Fire Brigade: Revised schedule of fees for the year 2026-27, BRC No. 69 dated 30.03.2026 (rows 1 to 6 and 28 read off the page images) (opens in a new tab)checked 24 October 2026
  10. Municipal Corporation of Greater Mumbai, Mumbai Fire Brigade: Public Appeal (DRAFT, undated; set a January 2016 upload deadline): submit Form B twice a year, in January and July (opens in a new tab)checked 24 October 2026
  11. Municipal Corporation of Greater Mumbai, Mumbai Fire Brigade: FB_06: documents for a new trade, including the undertaking-cum-indemnity bond on Rs 500 stamp paper (opens in a new tab)checked 24 October 2026
  12. Chief Fire Officer and Fire Advisor, Maharashtra Industrial Development Corporation: Circular MIDC/Fire/P-379286, 1 January 2025: Form B through the online SWC portal of MIDC only (opens in a new tab)checked 25 October 2026
  13. Maharashtra Fire and Emergency Services: MFS E-Approval online application, login page (opens in a new tab)checked 24 October 2026
  14. Municipal Corporation of Greater Mumbai, Mumbai Fire Brigade: Information of PIO and Appellate Officers of the Mumbai Fire Brigade (6 regional DFOs and 6 regional Deputy CFOs) (opens in a new tab)checked 24 October 2026
  15. Maharashtra Fire and Emergency Services: Contact us: Directorate of Maharashtra Fire Services, Kalina, Santacruz (East), Mumbai 400098 (opens in a new tab)checked 28 October 2026
  16. Mumbai Fire Brigade, Municipal Corporation of Greater Mumbai: Codified requirements of roof top serving area (2 pages, read with Public Health circular H0/25201/C of 10 November 2017) (opens in a new tab)checked 25 October 2026
  17. Municipal Corporation of Greater Mumbai, Mumbai Fire Brigade: List of mandatory documents for fire safety compliance of a nursing home under the Health Department, section 394 of the MMC Act (7 items) (opens in a new tab)checked 25 October 2026
  18. Municipal Corporation of Greater Mumbai, Mumbai Fire Brigade: List of documents for fire safety compliance of a nursing home under section 394 of the MMC Act (12 items: electrical audit, Form A and Form B, Rs 500 indemnity bond) (opens in a new tab)checked 25 October 2026
  19. Maharashtra Fire and Emergency Services: Guidelines for Form B, Annexure A: to be followed by licensed agencies issuing Form B under section 3(3) and rule 4(2) (circular of 7 July 2026) (opens in a new tab)checked 25 October 2026
  20. Free Press Journal: Mumbai fire safety alert: BMC launches citywide hotel inspection drive after Delhi blaze (5 June 2026) (opens in a new tab)News report · checked 24 October 2026
  21. Free Press Journal: Fire safety regulations: government issues notifications for Mumbai and the rest of Maharashtra following HC warning on development permits (12 October 2024) (opens in a new tab)News report · checked 28 October 2026
  22. Free Press Journal: BMC seizes illegal LPG cylinders and coal during fire safety drive ahead of New Year 2026: 2,703 establishments inspected (31 December 2025) (opens in a new tab)News report · checked 28 October 2026
  23. Free Press Journal: No more long waits: Maharashtra government reduces waiting period for civic services, fire NOC 12 days instead of 15 (28 June 2025) (opens in a new tab)News report · checked 28 October 2026
  24. Mumbaikar News: Mumbai tightens fire safety rules after Delhi hotel blaze; violators face utility disconnection (5 June 2026) (opens in a new tab)News report · checked 28 October 2026
  25. Free Press Journal, 9 July 2026: Maharashtra govt to audit gaming zones in malls, plans annual fire safety checks after Rajkot tragedy: 68 Mumbai malls inspected, 18 given 120-day notices (opens in a new tab)News report · checked 25 October 2026
  26. Wikipedia: Kamala Mills fire (29 December 2017): 14 dead at the 1Above rooftop bar and Mojo's Bistro, Lower Parel, Mumbai (opens in a new tab)News report · checked 25 October 2026
  27. The Business Standard (TBS News), 26 March 2021: Death toll in Mumbai mall fire rises to 10: Dreams mall, Bhandup, with Sunrise hospital on its top floor; BMC notice to the mall in November 2020 (opens in a new tab)News report · checked 25 October 2026
  28. Scroll.in, 22 January 2022: Mumbai: At least six dead, 15 injured after fire breaks out in 20-storey building (opens in a new tab)News report · checked 25 October 2026