Fire NOC for a guest house: the line in each state, the systems, fees and steps

Updated By Flamekite Editorial DeskFacts checked against official sources on

Quick answer

A guest house needs a fire NOC above 12 m or 4 storeys in Delhi, from G+2 in Puducherry and at any size in Goa and Shillong. Fire law treats it as lodging, not as a home: NBC 2016 puts guest houses in Group A-1, and Delhi, Himachal, Manipur, Chhattisgarh and Odisha draw a 12 m line for them, lower than the 15 m line for houses and flats.

Below the line a guest house still owes fire systems. A 2025 Delhi certificate for a 9-room guest house asked for 10 extinguishers, a hose reel on every floor, carbon monoxide detection and a terrace pump, and capped the use at the 2nd floor. Uttar Pradesh rates a guest house of 25 rooms as moderate risk at any height, and Goa and Sikkim ask for a fire NOC before tourism registration.

Delhi line for guest houses
12 m or 4 storeys
Mezzanine and stilt floors count
10 cases
Term of a 2025 Delhi guest-house certificate
3 years
The hotels term, not the 5-year home term
The inspection report
Rooms that make a UP guest house moderate risk
25
Or 12 m, 4 floors or 3 stars
Worked cases
Goa fee for lodging above 50 persons
Rs 10 per m²
The initial NOC is free
Fee schedules

Fire NOC for a guest house at a glance: 10 facts

What the codes, rules and a real certificate say about guest houses, each with its source.
WhatThe ruleSource
Code classA-1 lodging and rooming houses, a group that names guest houses (NBC 2016, clause 3.1.2); hotels up to four-star are A-5BIS, NBC 2016 Part 4
Code class from 2026A-I lodging and rooming houses; A-IV hotels up to four-star (NBCS 2026 Part F, voluntary)BIS, SP 7:2026
Delhi lineOver 12 m, or 4 or more storeys counting mezzanine and stilt floors (Rule 27(3), 26 May 2026)DFS
Uttar Pradesh risk classModerate from 12 m, 4 floors, 3 stars or 25 guest rooms (Form A-14, 2024 Rules)UP Rules 2024
Puducherry classCategory B from G+2: audit certificates from 2 licensed agencies, a yearly inspection, a 3-year NOCPuducherry G.O. 61
Goa tourism ruleA valid DFES NOC for registering or renewing a hotel or homestay, since 13 January 2026Goa Tourism order
Kerala lineGroup A2 lodging over 1,000 m² or over 15 m (KMBR rule 5(4))KMBR amendment 2025
Maharashtra, below 15 mLodging (A-1): extinguishers, sprinklers in a basement over 200 m², a 5,000 litre terrace tank above G+1MH Act 2023 Schedule-I
A real Delhi certificate9 guest rooms, use capped at the 2nd floor, valid 3 years from 1 January 2025DFS certificate 2025
Last verified25 October 2026, against each instrument and certificate named on this pageNot stated

Guest house fire NOC lines in 19 states and UTs, from the instruments

When a guest house or lodging house needs the fire certificate, how long it lasts, and the instrument that says so. Where the instrument is silent, the cell says so.
OptionWhen a guest house is coveredTerm or renewalInstrumentSource
DelhiOver 12 m, or 4 or more storeys counting mezzanine and stilt floors3 years for hotels until 20 May 2027; then valid until cancelled, with a yearly Form KDFS Rules 2010, Rule 27(3) as substituted on 26 May 2026DFS
MaharashtraLodging (A-1) has its own Schedule-I row from below 15 m; no lodging house above 45 mNot set in Schedule-IAct of 2006, Schedule-I as substituted in 2023MH Act 2023 Schedule-I
Uttar PradeshModerate risk at 12 m, 4 floors counting basements, 3 stars or 25 guest roomsRule 44 gives hotels 1 year; it does not name guest housesRules 2024, Forms A-14 and A-15UP Rules 2024
PuducherryCategory B at G+2 and above3 years, with 2 agency audit certificates on display and a yearly inspectionG.O.Ms.No.61, 10 September 2025Puducherry G.O. 61
GoaAny hotel; non-classified lodging under 15 m is a 10-day service for up to 15 or 25 rooms5 years under the notification of 23 June 2025RTS gazette of 3 November 2022, services 99 and 102Goa Gazette 2022
KeralaGroup A2 lodging over 1,000 m² or over 15 m; 300 to 1,000 m² files Appendix L insteadNot in rule 5(4)KMBR rule 5(4), items 12 and 13, as amended in 2025KMBR amendment 2025
TelanganaLodging and rooming houses above 18 mOnce in 5 years, risk class R4Circular Rc.No.4039-2/EODB/2015, 5 March 2016TSDRFS circular 2016
KarnatakaNo lodging line found; the Act's high-rise line is 21 m for any occupancyNo renewal publishedKarnataka Fire Force Act, section 13(3)CaseMinestudy
Himachal PradeshHotels and guest houses more than 12 m or ground plus 3 upper storeysNot statedSection 9 notification of 23 July 2019, item 4HP Home notification
ChhattisgarhHotels, lodgings and guest houses of 12 m, 500 m² built-up or 3 starsNot in this notificationSection 14(1) notification of 29 November 2022Home Department, Chhattisgarh
OdishaHotels, lodgings and guest houses of 12 m, 500 m² or 3 stars2 years; the district Assistant Fire Officer signs below 3 starsOrder 50908 of 2019Order 50908 of 2019
ManipurHotels and guest houses more than 12 m or G+3, mezzanine included3 years, hotels includedAct 9 of 2026, in force 14 September 2026Government of Manipur
NagalandHotels and guest houses more than 12 m; the G+3 words carry no "or"Not read for this pageAct 5 of 2023, section 21(1)Directorate of Fire and Emergency Services, Nagaland
MeghalayaAny lodge or homestay in Shillong and adjoining areas3 years since July 2025Notification HPL.127/2023/43 of 26 September 2024HPL.127/2023/43
MizoramLodging houses are a Third Schedule class; up to 15 rooms under 15 m need extinguishers onlyNot in the scheduleAmendment Rules of 20 August 2026Mizoram Home Dept
LakshadweepGuest houses and tourist stays of 30 or more rooms5 years under rule 12Rules 2026, rules 8 and 11(2)Lakshadweep Gazette Extraordinary Vol. LXII No. 42, 3 September 2026
PunjabNo guest-house line found; the 2021 fee letter prices hotels in Zone 2Not stated in the letterLetter No. S4-DSMS-(Fire)-2021/41343 of 8 October 2021Local Govt Punjab
RajasthanNo guest-house line; every building above 15 m is high riskNot publishedUDH model building regulations, 2025Rajasthan UDH
Jammu and KashmirHotels and guest houses take a Final Registration NOC (Ganderbal's service list)Not shownDistrict Ganderbal fire services page, 2022District Ganderbal

How to get a fire NOC for a guest house: 8 steps

  1. Fix the class the officer will record

    Decide whether the building is a guest house or lodging house (NBC A-1, Kerala A2) or a hotel (A-5). In Maharashtra the class changes the systems below 15 m, so settle it with your architect before drawing anything.

  2. Measure height and count storeys the state's way

    Delhi counts mezzanine and stilt floors as storeys; Uttar Pradesh also counts basements. A ground, mezzanine and 3-floor guest house is 5 storeys in Delhi.

  3. Count rooms and stars

    25 guest rooms make a UP guest house moderate risk at any height, 30 rooms bring a Lakshadweep guest house under the provisional certificate, and Goa sorts lodging by 15 and 25 rooms.

  4. Check what your tourism or trade registration asks

    Goa and Sikkim list a fire NOC among the documents for a hotel or guest house; a J&K guest house takes a Final Registration NOC. Get the fire paper before you file the registration.

  5. Have the fire plan drawn and the systems installed

    In Puducherry a Category B building needs a fire plan by a licensed agency on the building plan. Install the systems your class and height call for, and keep the installer's test records.

  6. Apply online with the room count

    Upload the plans, ownership proof and the occupancy floor by floor. Puducherry's form asks for the rooms of a lodging house; Delhi's certificate lists the rooms on each floor.

  7. Be present at the inspection

    DFS inspected a 9-room guest house against 20 heads with the owner present. Expect the officer to cap the floors you may use if the stairs or exits fall short.

  8. Diary the renewal and the yearly filings

    Delhi asks for renewal six months before expiry, UP 1 month before on Form A-11. Use the renewal date calculator, and file Delhi's Form K every year from 20 May 2027.

Where a guest house sits in the fire codes: NBC A-1, Kerala A2, Delhi's 3 years

Fire codes do not treat a guest house as a home. The class decides which line and which systems apply.

A-1, NBC 2016
Lodging and rooming houses: inns, clubs, motels and guest houses. A lodging house where no room is let to more than 3 persons counts as an A-2 dwelling. BIS, NBC 2016 Part 4
A-2, NBC 2016
One or two-family private dwellings sleeping up to 20 persons. It is not the guest house class. BIS, NBC 2016 Part 4
A-5 and A-6, NBC 2016
Hotels up to four-star (A-5) and starred hotels of five stars and above (A-6). BIS, NBC 2016 Part 4
A-I and A-IV, NBCS 2026
The 2026 code's names for lodging houses and hotels up to four-star; the code is voluntary and Part F renumbers the groups. BIS, SP 7:2026
A2, Kerala
"Lodging houses and special residential" in rule 25(1) of the Kerala building rules: Kerala's own group, not NBC's A-2. KMBR amendment 2025
Residential A-1, Delhi
The occupancy DFS wrote on a guest-house certificate of 1 January 2025, which it issued for 3 years, the term for hotels. DFS certificate 2025
Hotels, lodgings and guest houses, UP
One heading in Form A-14 of the 2024 Rules, with its own 12 m, 4-floor and 25-room lines. UP Rules 2024

Delhi Rule 27(3): the guest house line in the 2026 text

Delhi's substituted Rule 27 has separate items for homes and for hotels and guest houses. The guest house line is lower by 3 m and by 1 storey.

Word for word

(2) Residential buildings (other than hotels and guest houses) having height more than 15 meters or comprised of Five or more stories, including mezzanine/stilt floor above ground level. (3) Hotels and guest houses building having height more than 12 meters or comprised of four or more stories, including mezzanine/stilt floor above ground level.

Delhi Fire Service (Amendment) Rules, 2025, rule 27 as substituted, in force on publication on 26 May 2026 DFS

The DFS FAQ page still prints the 2010 wording, "having height more than 12 meters having ground plus three upper stories", without the "or". The gazetted 2026 text is the one in force: either test alone brings a guest house in.

Does your guest house need a fire NOC? 10 cases

Find the first line that fits your building. Crossing any one test in your state is enough.

  1. If Delhi, over 12 m or 4 storeys, counting mezzanine and stilt

    Yes: a DFS Fire Safety Certificate. The line for guest houses is 12 m or 4 storeys, against 15 m or 5 storeys for homes. Fire NOC Delhi DFS

  2. If Puducherry, ground plus 2 floors or more

    Category B: a fire plan by a licensed agency at plan stage, audit certificates from 2 agencies, a yearly inspection and a NOC for 3 years. Fire NOC Puducherry Puducherry G.O. 61

  3. If Puducherry, a non-residential ground plus 1

    Category C: a self-attested statement on the portal generates the fire safety protocol certificate; a quarter may be inspected. Puducherry G.O. 61

  4. If Uttar Pradesh, 25 guest rooms or more, or 12 m, 4 floors or 3 stars

    Moderate risk in Form A-14. 100 rooms or 4 stars also need a Fire Safety Officer round the clock. Fire NOC UP UP Rules 2024

  5. If Goa, a guest house registering with Tourism

    Yes, at any size: a valid DFES NOC is a document for new registration and every renewal since 13 January 2026. Fire NOC Goa Goa Tourism order

  6. If Shillong and adjoining areas

    Yes, at any size: hotels, lodges, homestays and resorts need a fire NOC under the notification of 26 September 2024. Fire NOC Meghalaya HPL.127/2023/43

  7. If Kerala, lodging over 1,000 m² or over 15 m

    Yes. Between 300 m² and 1,000 m², up to 15 m, the owner files an Appendix L self-declaration with a copy to the nearest fire station. Fire NOC Kerala KMBR amendment 2025

  8. If Telangana, above 18 m

    Yes: lodging and rooming houses are covered above 18 m. The 24 m change of 7 October 2026 is for apartments only. Fire NOC Telangana TGFD circular 3455

  9. If Himachal, Manipur or Nagaland, more than 12 m

    Yes. Himachal and Manipur also catch ground plus 3 upper storeys; Nagaland's text has no "or" before G+3. Fire NOC Himachal Pradesh HP Home notification

  10. If Below every line in your state

    No certificate, but your state's minimum systems still apply. In Maharashtra a lodging house below 15 m keeps extinguishers and, above G+1, a 5,000 litre terrace tank. Do I need a fire NOC? MH Act 2023 Schedule-I

Maharashtra guest house systems below 15 m: lodging (A-1) or hotel (A-5)

Schedule-I of the Maharashtra Act sets the systems by class and height. Below 15 m a guest house recorded as lodging needs far less than one recorded as a hotel. Read off the 2023 gazette's page images.

ExtinguishersHose reelAlarm and detectionSprinklersTerrace tankTerrace pump
Lodging (A-1), below 15 m MH Act 2023 Schedule-IRequiredNot requiredNeither requiredOnly in a basement over 200 m²5,000 litres above ground plus 1Not required
Lodging (A-1), 15 m to 35 m MH Act 2023 Schedule-IRequiredRequired, with a down comerManual alarm requiredOnly in a basement over 200 m²25,000 litres900 litres a minute
Lodging (A-1), above 35 m to 45 m MH Act 2023 Schedule-IRequiredRequired, with a wet riserManual alarm and automatic detectionRequired (Notes 4 and 15(a))5,000 litres, plus a 75,000 litre underground tankPumps at the underground tank (Note 10)
Hotel (A-5), below 15 m, no floor over 500 m² MH Act 2023 Schedule-IRequiredRequiredManual alarm requiredOnly in a basement over 200 m²5,000 litres, 5,000 more with a large basement450 litres a minute
Hotel (A-5), below 15 m, a floor of 500 m² to 1,000 m² MH Act 2023 Schedule-IRequiredRequired, with a down comerManual alarm and automatic detectionOnly in a basement over 200 m²20,000 litres450 litres a minute

Note 3(d) of the Schedule bars lodging houses (A-1) above 45 m. Note 10's pump set is one 2,280 litre a minute electric pump, one diesel standby and one 180 litre a minute jockey per 100 hydrants.

Guest house fire NOC worked cases: 7 buildings

Each case applies one state's instrument to a described building. The first is a real certificate; the rest are Flamekite's worked examples.

  1. Case 1

    A 9-room guest house in Paharganj, Delhi

    Ground, mezzanine and 3 upper floors, built in 1982; 4 guest rooms on the 1st floor and 5 on the 2nd.

    What applies DFS renewed its certificate from 1 January 2025 for 3 years, for use up to the 2nd floor only, on the owner's 2022 affidavit not to use the floors above. Counting the mezzanine it has 5 storeys. DFS certificate 2025

  2. Case 2

    A 28-room guest house in Lucknow, 11 m, 3 floors

    Lodging under 12 m and under 4 floors.

    What applies Moderate risk in Form A-14 all the same, because it has 25 guest rooms or more. UP Rules 2024

  3. Case 3

    A ground plus 2 guest house in Puducherry

    Lodging on 3 floors.

    What applies Category B: the building plan carries a licensed agency's fire plan, no separate plan-stage NOC is issued, and at occupancy the chosen empanelled agency reports. The NOC lasts 3 years. Puducherry G.O. 61

  4. Case 4

    A 20-room lodging house in Calangute, Goa, 10 m

    Non-classified lodging under 15 m.

    What applies DFES service 99 (lodging up to 25 rooms): the Divisional Officer decides in 10 days. Tourism will not register or renew it without that NOC. Goa Gazette 2022

  5. Case 5

    A 900 m² lodging house in Kochi, 12 m

    Group A2, under 1,000 m² and 15 m.

    What applies No fire NOC. The owner signs Appendix L with an architect's or engineer's certificate and sends a copy to the nearest fire station. KMBR amendment 2025

  6. Case 6

    A 14 m, 4-floor lodging house in Pune

    Recorded as lodging (A-1), no floor over 500 m², no basement.

    What applies Extinguishers and a 5,000 litre terrace tank. Recorded as a hotel (A-5), the same building adds hose reels, a manual alarm and a 450 litre a minute terrace pump. MH Act 2023 Schedule-I

  7. Case 7

    A 16 m, 20-room guest house in Hyderabad

    Lodging and rooming house.

    What applies Below Telangana's 18 m lodging line, so no NOC under the 2016 circular; at 19 m it would renew once in 5 years as low risk. TSDRFS circular 2016

What DFS checked at a 9-room Delhi guest house: 12 report lines

The inspection report behind a DFS guest-house certificate of 1 January 2025 runs to 20 heads. These 12 lines show what an officer measured, read off the scanned pages.

  • Occupancy written floor by floor: reception and restaurant on the ground, 4 store rooms on the mezzanine, 9 guest rooms on floors 1 and 2, 2 staff rooms on floor 3 DFS certificate 2025
  • Road width at the gate: 4 m recorded DFS certificate 2025
  • Staircases: 1 required and 1 provided, running continuously to the terrace DFS certificate 2025
  • Stair width: 0.80 m required for this old building, 1.16 m found, marked "MR (Old case)" DFS certificate 2025
  • Extinguishers: 10 required and 10 found, ABC and CO2 types, ISI marked DFS certificate 2025
  • First-aid hose reel: 1 on each floor, 30 m of hose, 5 mm nozzle DFS certificate 2025
  • Automatic detection with CO-type detectors, a main panel, an alternate power source and hooters DFS certificate 2025
  • A manually operated electric fire alarm (MOEFA): required and provided DFS certificate 2025
  • A terrace pump of 180 litres a minute at 30 m head, with its own power supply and auto start DFS certificate 2025
  • Exit signs and standby power: required and provided DFS certificate 2025
  • Marked not applicable: sprinklers, hydrants, public address, lifts, refuge area and a fire control room DFS certificate 2025
  • The result: "substantial compliance" and a renewal recommended up to the 2nd floor, for 3 years, with a Form K declaration every year DFS certificate 2025

Tourism and trade registration for a guest house: 6 regimes

In some states the fire NOC is a document for registering the business, not only for the building. Here is what each regime asks.

  • Since 13 January 2026

    Goa

    A valid DFES NOC for new registration and every renewal of hotels, homestays and other tourist trades. Goa Tourism order

  • Form II, 2025 Rules

    Sikkim

    The document list for "Hotels / Lodge / Resort / Guest House" asks for a NOC from the Fire department, among others; registration runs 1 year and is renewed every year. Sikkim Tourist Trade Rules

  • Single window

    Jammu and Kashmir

    Ganderbal lists a Final Registration NOC for hotels, guest houses, restaurants and joinery mills: site plan, building plan, revenue record or rent deed, photograph and application. District Ganderbal

  • Shillong, 2024

    Meghalaya

    Every hotel, lodge, homestay and resort in Shillong and adjoining areas needs a compulsory fire NOC, with no size line. HPL.127/2023/43

  • No fire paper listed

    Himachal Pradesh

    The tourism unit registration form lists plans, completion reports and a Pollution Control Board NOC, but no fire NOC; the fire line comes from the 2019 notification instead. HP Tourism forms

  • Reported, June 2025

    Delhi

    News reports say Delhi withdrew the Delhi Police licence for hotels, motels and guest houses, leaving licensing to the MCD, NDMC or Cantonment Board; the fire certificate is unchanged. The Weeknews report

Guest house fire NOC fees in official schedules

Only a few states print a rate that reaches a guest house. Each line below is from an official schedule; where none is published, the line says so.

As published

  • Goa, initial NOCFreeThen Rs 10 per m² of built-up area for hotels and lodging for more than 50 persons DFES Goa
  • Goa, guest house up to 50 m²1 extinguisher and a Rs 100 stamp paperA self-declaration under Annexure III; 2 extinguishers from 50 m² to 100 m² DFES Goa charter
  • Meghalaya, guest house up to 40 personsRs 4 per m²Annual renewal fee Rs 500; Rs 1,000 for 40 to 100 persons Meghalaya F&ES
  • Chandigarh, lodging (A-1)Rs 6,615 or Rs 14 per m²Whichever is more; certificate 5 years since 6 May 2026; A-2 houses are exempt MCC Office Order 23
  • TelanganaRs 10 per m²Of total built-up area G.O.Ms.No.142
  • Kerala, hotels (A5, A6)Rs 40 per m²Minimum Rs 20,000; the A2 lodging rate was not confirmed for this page Kerala Fire and Rescue Services
  • Punjab, Zone 2 hotels up to 15 m on under 200 sq ydRs 10,0002021 letter; guest houses are not named in a zone Local Govt Punjab
  • DelhiNot published todayRs 1,000 with each yearly Form K from 20 May 2027 DFS
  • Uttar PradeshNilThe UP fire service dashboard lists no fee UP Fire dashboard
  • PuducherryFreeCitizen Charter: issue of a NOC or licence Fire Service Department, Puducherry

Fees are what the schedules print; your portal's demand note decides the amount. Consultant or agency charges are not fees and are not listed here. All state rates side by side are on the fire NOC fees page.

Guest house fire NOCs in numbers

The counts and lines a guest house owner meets most often, each from its source.

Renewing a guest house fire certificate in 6 states

Terms run from 2 to 5 years for guest houses. Each stop is one state's renewal rule.

  1. Delhi, until 20 May 2027

    Renew six months before expiry. The 2025 guest-house certificate sends the renewal to the MHA portal and asks for a Form K declaration every year. DFS certificate 2025

  2. Delhi, from 20 May 2027

    The certificate stays valid until cancelled, kept alive by a yearly online Form K with Rs 1,000; the start was deferred by the gazette of 16 October 2026. Delhi Gazette

  3. Uttar Pradesh

    Apply on Form A-11 at least 1 month before expiry, and file the Form A-8 maintenance certificate every January and July. UP Rules 2024

  4. Puducherry

    A Category B NOC is renewed every 3 years; keep the QR-coded NOC on display and hold 1 fire drill a year under the department's supervision. Puducherry G.O. 61

  5. Goa

    A NOC lasts 5 years under the Home Department notification of 23 June 2025. Government of Goa, Official Gazette Series II No. 14, 3 July 2025

  6. Odisha and Telangana

    Odisha's lodging and guest-house certificate runs 2 years; Telangana renews lodging above 18 m once in 5 years. Order 50908 of 2019

What a guest house risks without a valid fire certificate

Penalties come from the fire Acts and rules. A guest house also risks its trade licence where the rules link the two.

OffencePenaltyLaw
Breaching the fire safety chapter (Delhi)Up to 6 months or Rs 50,000 or both, and up to Rs 3,000 a dayDelhi Fire Service Act 2007, section 37 Caseminestudy
Compounding an offence (Delhi)A Deputy CFO up to Rs 10,000, a CFO up to Rs 50,000, the Director above thatDFS Rules, rule 43 as amended in 2026 DFS
Shortcomings left unremedied (Delhi)The building declared unfit; electricity and water disconnectedDFS Rules 2010, rule 38(3) Delhi Fire Service
Letting fire systems lapse (Maharashtra)Rigorous imprisonment of 6 months to 3 years and a fine of Rs 20,000 to Rs 50,000Maharashtra Act 2006, section 36(1) MFS Act 2006 copy
A cancelled certificate (Uttar Pradesh)Reported to the licensing authority to cancel the hotel's licenceUP Rules 2024, rule 46 UP Rules 2024
Self-declared systems found ineffective (Kerala)Rs 100 per m² of built-up area, up to Rs 1,00,000KMBR 2019, Appendix L KMBR 2019
Ignoring notified precautions (Goa)A penalty up to Rs 10,000Goa Fire Force Act, section 21 as amended by Ordinance 4 of 2025 Goa Ordinance 4 of 2025

Every state's penalty ladder is on the fire NOC penalties page.

Where guest houses fail a fire inspection, and the fix

These are the 6 failures the instruments and certificates point to for guest houses.

  • If Guests on floors the certificate leaves out

    Use only the floors named. DFS capped a 9-room guest house at the 2nd floor on the owner's affidavit; extend the systems and exits before you open more floors, then apply again. DFS certificate 2025

  • If Counting storeys without the mezzanine or stilt

    Count them. Delhi's Rule 27(3) includes mezzanine and stilt floors, so a ground plus 3 with a mezzanine has 5 storeys. DFS

  • If Wooden or foam panelling in the stairway

    Strip it. Clause 7.11 of Delhi's building bye-laws bars combustible decoration and wall panelling in a staircase. DDA, UBBL 2016

  • If A 1 m stair in a new guest house

    Draw 1.5 m. The bye-laws set 1.5 m for guest houses; the 0.80 m DFS accepted in 2024 was for a 1982 building. DDA, UBBL 2016

  • If Registering as a hotel but fitting lodging-house systems

    Match the class. In Maharashtra a hotel below 15 m needs hose reels, a manual alarm and a 450 litre a minute terrace pump that lodging does not. MH Act 2023 Schedule-I

  • If Forgetting the yearly declaration

    Diary it. The DFS certificate makes a Form K declaration every year a condition of validity. DFS certificate 2025

Turning a house into a guest house: 5 dos and 4 don'ts

A change of use can cross a lower fire line overnight. Test the new use, not the old one.

Do

  • Test the building against the guest-house line: in Delhi that is 12 m or 4 storeys, not the 15 m or 5 storeys for homes. DFS
  • Get the occupancy changed first: NBC 2016 needs a certificate of occupancy before any change of occupancy, and the new group's rules then apply. BIS, NBC 2016 Part 4
  • Count the rooms in Uttar Pradesh: 25 guest rooms put the building in moderate risk at any height. UP Rules 2024
  • Plan the 5,000 litre terrace tank in Maharashtra once the building is above ground plus 1. MH Act 2023 Schedule-I
  • In Kerala, file Appendix L from 300 m² even below the NOC line. KMBR amendment 2025

Don’t

  • Don't rely on the old certificate: DFS issues it for an occupancy class, floor by floor. DFS certificate 2025
  • Don't treat a fire certificate as regularising the building: condition 5 of the DFS certificate says it cannot. DFS certificate 2025
  • Don't plan a lodging house above 45 m in Maharashtra: Note 3(d) bars it. MH Act 2023 Schedule-I
  • Don't count on Ladakh's 12.5 m guest-house exemption: the press release of 16 October 2025 calls it a proposal. Ladakh DIPR

Guest house fire NOC myths, checked against the rules

5 claims owners repeat, and what the instruments say.

  • You may have read

    A guest house is a house, so the 15 m home line applies.

    Myth

    What the sources say

    Delhi sets 12 m or 4 storeys for hotels and guest houses, against 15 m or 5 storeys for homes; Himachal and Manipur also use 12 m. DFS

  • You may have read

    NBC puts guest houses in A-2.

    Myth

    What the sources say

    NBC 2016 names guest houses in A-1, lodging and rooming houses. A-2 is the one or two-family dwelling; Kerala's A2 is a different, state group. BIS, NBC 2016 Part 4

  • You may have read

    A small guest house never needs a fire NOC.

    Myth

    What the sources say

    In Shillong every lodge needs one at any size, and Goa asks for one before any tourism registration. HPL.127/2023/43

  • You may have read

    Guest house fire NOCs must be renewed every year.

    Myth

    What the sources say

    Puducherry's Category B NOC runs 3 years, Goa's 5 and a 2025 Delhi guest-house certificate 3. Puducherry G.O. 61

  • You may have read

    Delhi bans guest houses above 4 floors.

    Myth

    What the sources say

    News reports of 27 May 2019 say the bye-law amendment stopped fire NOCs for guest houses above 4 floors, excluding basement and stilt. Flamekite could not find the notification itself. India TVnews report

Guest house fire rules, dated: 2014 to 2026

The instruments that set or changed a guest house's fire duties, in order.

  1. 17 December 2014

    Goa's section 13 notification lists hotels, restaurants and bakeries at any size. DFES Goa charter

  2. 5 March 2016

    Telangana sets 18 m for lodging and rooming houses. TSDRFS circular 2016

  3. 17 May 2018

    Goa's Annexure III sets extinguishers for guest houses up to 100 m². DFES Goa charter

  4. 6 March 2019

    Odisha covers hotels, lodgings and guest houses at 12 m, 500 m² or 3 stars. Odisha Rules 2019

  5. 27 May 2019

    Delhi's guest-house bye-law amendment is notified for the 3 MCDs, as reported. India TVnews report

  6. 23 July 2019

    Himachal lists hotels and guest houses above 12 m or G+3. HP Home notification

  7. 18 January 2024

    UP's Rules add Form A-14, with its 25-room line for guest houses. UP Rules 2024

  8. 26 September 2024

    Shillong makes a fire NOC compulsory for every lodge and homestay. HPL.127/2023/43

  9. 1 January 2025

    DFS renews a 9-room Paharganj guest house's certificate for 3 years, up to the 2nd floor. DFS certificate 2025

  10. 10 September 2025

    Puducherry puts guest houses of G+2 in Category B. Puducherry G.O. 61

  11. 13 January 2026

    Goa ties tourism registration to a DFES NOC. Goa Tourism order

  12. 26 May 2026

    Delhi's substituted Rule 27(3) adds "or": 12 m or 4 storeys. DFS

  13. 16 October 2026

    Delhi defers Form K and the valid-until-cancelled certificate to 20 May 2027. Delhi Gazette

Delhi guest houses after Karol Bagh (2019) and Malviya Nagar (2026)

From news reports, not yet an official source.

News reports only: Flamekite found no official order text for these steps on 25 October 2026. The rules in force are on the Delhi fire NOC page.

  • After the Hotel Arpit Palace fire in Karol Bagh, Delhi's Home Minister said about 200 guest houses had been inspected and the fire certificates of about 150 cancelled, with the licensing department, police, health department and North DMC asked to shut them. The Quintnews report

  • A notification with 10 amendments to Delhi's 2016 building bye-laws is reported: no fire NOC for guest houses above 4 floors, floor plans showing each floor's use, carbon monoxide detectors, 1-hour fire doors at stairs and no cooking on rooftops or in basements. India TVnews report

  • Delhi Police licences for hotels, motels and guest houses are reported withdrawn after the Lieutenant Governor's order of 19 June, with licensing passing to local bodies. The Weeknews report

  • After 21 died in a Malviya Nagar guest house on 3 June, the Revenue Department served notices on 72 sites. UNInews report

Where a guest house applies: 5 official fire portals

Apply on the fire service's own portal or single window. These 5 are linked from official pages Flamekite read.

What Flamekite could not confirm about guest house fire NOCs

These 6 points are where a reader would expect an answer and no official source gave one on 25 October 2026.

  • The text of Delhi's guest-house bye-law amendment of 27 May 2019. Only news reports and secondary summaries were found, so this page treats its 4-floor rule as reported.
  • Whether Uttar Pradesh's 1-year term in rule 44 covers guest houses. The rule names hotels; Forms A-14 and A-15 group hotels, lodgings and guest houses.
  • Kerala's fee for Group A2 lodging, and the Punjab fee zone a guest house falls in.
  • Any lodging line in Karnataka's or Rajasthan's fire rules, beyond their general 21 m and 15 m lines.
  • The overhead tank figure on the 2024 DFS guest-house inspection report, printed "25,00ltr": it could be 2,500 or 25,000 litres.
  • Where a Delhi guest house renews its fire certificate after the 2025 change in police licensing: the 2025 certificate says the MHA portal, and DFS still links it.

Questions about fire NOCs for guest houses

Is a fire NOC mandatory for a guest house?

Only above your state's line, which is usually lower than for houses. Delhi covers guest houses over 12 m or with 4 or more storeys, Puducherry from ground plus 2 floors, Telangana above 18 m, and Goa and Shillong at any size. Below the line a guest house still needs the minimum systems its state sets.

What is the fire NOC rule for a guest house in Delhi?

Rule 27(3) of the Delhi Fire Service Rules, as substituted on 26 May 2026, covers hotels and guest houses over 12 m or of 4 or more storeys, counting mezzanine and stilt floors. DFS then issues a Fire Safety Certificate; a 2025 guest-house certificate ran 3 years.

Which NBC occupancy is a guest house?

Group A-1, lodging and rooming houses, which NBC 2016 says includes guest houses. Hotels up to four-star are A-5. Kerala's building rules use their own Group A2 for lodging houses.

What fire equipment does a small guest house need?

It depends on the state and height. A 9-room Delhi guest house was checked for 10 extinguishers, a 30 m hose reel on each floor, carbon monoxide detection, a manual alarm and a 180 litre a minute terrace pump. In Maharashtra a lodging house below 15 m needs extinguishers and, above ground plus 1, a 5,000 litre terrace tank.

How long is a guest house fire NOC valid?

2 years in Odisha, 3 years in Delhi (the hotels term), Puducherry and Meghalaya, and 5 years in Goa. Delhi moves to a certificate valid until cancelled, with a yearly Form K, from 20 May 2027.

Do I need a fire NOC to register a guest house with tourism?

In Goa yes, for registration and every renewal since 13 January 2026. Sikkim's guest-house document list asks for a NOC from the Fire department, and J&K guest houses take a Final Registration NOC. Himachal's tourism form lists no fire NOC.

How much does a guest house fire NOC cost?

Few states publish a rate. Goa's initial NOC is free and its licence fee is Rs 10 per m² for lodging above 50 persons; Meghalaya charges Rs 4 per m²; Chandigarh Rs 6,615 or Rs 14 per m²; Telangana Rs 10 per m². Uttar Pradesh and Puducherry charge nothing.

Can a Delhi guest house use all its floors?

Only the floors its certificate names. DFS renewed one Paharganj guest house in 2025 for use up to the 2nd floor only, on the owner's affidavit not to use the floors above.

Keep reading

Free tools for this

Words on this page, explained

Keep exploring

Sources

Each source was opened and read on the date shown. How Flamekite checks its sources

  1. Delhi Fire Service (copy of Delhi Gazette Extraordinary, Part IV): Delhi Fire Service (Amendment) Rules, 2025, notification F.No. DFS/HQ/Misc/2025/01(E-259159)/237, gazetted 26 May 2026 (opens in a new tab)checked 25 October 2026
  2. Delhi Fire Service: Frequently asked questions (opens in a new tab)checked 25 October 2026
  3. Delhi Fire Service, Govt of NCT of Delhi (scan hosted on delhi.gov.in): Fire Safety Certificate No. F6/DFS/MS/2024/GH/01 of 1 January 2025 for a 9-room Paharganj guest house, with its inspection report of 19 December 2024 (read off the page images) (opens in a new tab)checked 25 October 2026
  4. Government of Maharashtra (gazette copy hosted by Maharashtra Fire and Emergency Services): Maharashtra Fire Prevention and Life Safety Measures (Amendment) Act, 2023, substituted Schedule-I: rows (a) lodging and rooming houses (A-1) and (c) hotels (A-5), with Notes 3(d), 4, 5 and 10 (read off the page images, pp. 13 to 16, 32 and 33) (opens in a new tab)checked 25 October 2026
  5. Uttar Pradesh Gazette Extraordinary, 18 January 2024 (copy hosted by UP Fire and Emergency Services): Uttar Pradesh Fire and Emergency Services Rules, 2024: Form A-14, risk category of occupancies (hotels, lodgings and guest houses), and Form A-15, Fire Safety Officer for hotels and guest houses of 100 rooms (gazette pages 132 and 133) (opens in a new tab)checked 25 October 2026
  6. Government of Puducherry, Home Department (copy hosted by the Fire Service Department): G.O.Ms.No.61, 10 September 2025: Fire Safety Audit and Issue of NOC, Third Party Fire Safety Audit, Categories A, B and C, renewal, temporary licences, and Annexures I to V on licensed agencies and the Category C protocol (opens in a new tab)checked 25 October 2026
Show all 54 sourcesShow fewer
  1. Bureau of Indian Standards (BIS-licensed copy hosted by Nagpur Municipal Corporation): National Building Code of India 2016 (SP 7:2016), Part 4: Fire and Life Safety, clauses 1.2, 2.38 and 3.1 (opens in a new tab)checked 25 October 2026
  2. Government of Goa, Official Gazette Series I No. 42 (Extraordinary), 16 January 2026 (copy hosted by the Department of Tourism): Department of Tourism order N5/3(865)/2025-26/DT/339, 13 January 2026: documents for registration and renewal of hotels, homestays, shacks, water sports and other tourist trades, with the corrigendum of 29 January 2026 (opens in a new tab)checked 25 October 2026
  3. Government of Goa, Official Gazette Series II No. 14, 3 July 2025: Home Department notification 3/14/2024-HD(G)/1652, 23 June 2025: 5-year fire NOC validity (opens in a new tab)checked 25 October 2026
  4. Local Self Government Department, Government of Kerala (Kerala Gazette Extraordinary No. 3808): Kerala Municipality Building (Amendment) Rules, 2025 (G.O.(P) No.53/2025/LSGD, S.R.O. No.1240/2025, 29 October 2025) and Kerala Panchayat Building (Amendment) Rules, 2025 (G.O.(P) No.54/2025/LSGD): rule 5(4) restated, rules 35 and 36 (opens in a new tab)checked 25 October 2026
  5. Bureau of Indian Standards (copy hosted by Goa Directorate of Fire and Emergency Services): SP 7:2026 National Building Construction Standards 2026, Part F: Fire and Life Safety (opens in a new tab)checked 25 October 2026
  6. Home (Police) Department, Government of Meghalaya: Notification No. HPL.127/2023/43 of 26 September 2024: compulsory fire NOC for hotels, lodges, homestays, resorts and business buildings in Shillong city and adjoining areas (opens in a new tab)checked 24 October 2026
  7. Telangana Fire, Disaster Response, Emergency and Civil Defence Department: Circular Memorandum Rc.No.3455/MSB/2026, 26 September 2026: revised requirements for Fire NOCs in the context of G.O.Ms.No.95 (in force 7 October 2026) (opens in a new tab)checked 25 October 2026
  8. Government of Himachal Pradesh, Department of Home (copy hosted by the Department of Fire Services): Notification No. Home-F(A)3-1/2019-I, 23 July 2019, under section 9(1) of the HP Fire Fighting Services Act, 1984: 17 classes of premises and 20 fire precautions, English and Hindi texts (opens in a new tab)checked 25 October 2026
  9. Government of Goa, Official Gazette Series II No. 31 (Extraordinary No. 3), 3 November 2022: Notification 41/1/2022/PG(Notification)/235 under the Goa (Right of Citizens to Time-bound Delivery of Public Services) Act, 2013: DFES services 81 to 116 with designated officers, time limits and appellate authorities (opens in a new tab)checked 24 October 2026
  10. Telangana State Disaster Response and Fire Services Department: Circular Memorandum Rc.No.4039-2/EODB/2015, 5 March 2016: revision of the period of renewal of NOC, risk categories and random inspections (quotes section 13 of the Fire Service Act, 1999) (opens in a new tab)checked 25 October 2026
  11. Government of Sikkim, Sikkim Government Gazette Extraordinary No. 37, 5 March 2025: The Sikkim Registration of Tourist Trade Rules, 2025, Tourism and Civil Aviation Department notification No. 01/DoT&CAv, 4 March 2025, with Forms I to VII (opens in a new tab)checked 24 October 2026
  12. District Administration Ganderbal, Government of Jammu and Kashmir: Fire & Emergency: Final Registration NOC for hotels, guest houses, restaurants and joinery mills, and Provisional Registration (updated 23 July 2022) (opens in a new tab)checked 24 October 2026
  13. Department of Tourism and Civil Aviation, Himachal Pradesh: Application forms and document lists for registration of tourism units, travel agents, guides, restaurants and adventure operators under the HP Tourism Development and Registration Act, 2002 (opens in a new tab)checked 24 October 2026
  14. Directorate of Fire and Emergency Services, Goa: Acts, Rules, Citizen's Charter and RTI: fee schedule of the Goa State Fire Force Rules, including stand-by appliances at Rs 2,000 a day (opens in a new tab)checked 24 October 2026
  15. Directorate of Fire and Emergency Services, Goa: Citizen's Charter, December 2024: 17 fire stations, 3 zones, 1,106 posts, the section 13 notification 3/5/97-HD(G) Part/3934 of 17 December 2014 with Annexures I and II, the 2018 Annexure III on shacks and guest houses, and the 2009 fee rules (opens in a new tab)checked 25 October 2026
  16. Fire and Emergency Services, Meghalaya: Annexure B (with continuation sheets B1 and B2) to notification HPL.179/2017/85: fees per m² and annual renewal fees for every building category (opens in a new tab)checked 24 October 2026
  17. Municipal Corporation Chandigarh, Fire and Rescue Services: Office Order No. 23 of 10 February 2025: Fire Safety Certificate charges by NBC occupancy group from 1 April 2025, validity 3 years, exemptions (read from the page images) (opens in a new tab)checked 25 October 2026
  18. Government of Telangana, Home (Ser.IV) Department: G.O.Ms.No.142, Home (Ser.IV), 9 August 2016: fire precaution fee amending the Levy of Fee Rules, 2006 (opens in a new tab)checked 24 October 2026
  19. Kerala Fire and Rescue Services: Fee structure, G.O.(Ms)No.272/2024/Home (opens in a new tab)checked 24 October 2026
  20. Directorate of Local Government, Punjab (Wayback Machine copy of 21 March 2022 of the portal's fee download): Letter No. S4-DSMS-(Fire)-2021/41343 of 8 October 2021: new fees for online fire NOCs, by NBC zone, with provisional, renewal and 30-day rules (opens in a new tab)checked 25 October 2026
  21. Uttar Pradesh Fire and Emergency Services: Dashboard: provisional, final and renewal applications, approvals and days to certificate (printed 24 October 2026) (opens in a new tab)checked 24 October 2026
  22. Fire Service Department, Puducherry: Services: issue of fire NOC or licence, free (categories and validity are in G.O.Ms.No.61, source py-go61-scan) (opens in a new tab)checked 24 October 2026
  23. Lakshadweep Gazette Extraordinary Vol. LXII No. 42, 3 September 2026: Lakshadweep Fire and Emergency Services Rules, 2026 (Rule 12: 5-year fire safety certificate) (opens in a new tab)checked 24 October 2026
  24. Department of Tourism and Civil Aviation, Himachal Pradesh: Statistics of hotels, guest houses, restaurants, home stay units and bed capacity by district, December 2019 to December 2025 (opens in a new tab)checked 24 October 2026
  25. Delhi Gazette Extraordinary, Part IV (Home Department, Govt of NCT of Delhi): Notification F. No. 6/DFS/MS/HQ/MISC/2026/01/631, 16 October 2026 (No. 314, SG-DL-E-17102026-277257): commencement of Rules 34 to 38 and the First and Seventh Schedules extended to 20/05/2027 (opens in a new tab)checked 25 October 2026
  26. Uttar Pradesh Gazette Extraordinary, 18 January 2024 (copy hosted by UP Fire and Emergency Services): Uttar Pradesh Fire and Emergency Services Rules, 2024, Notification No. 181/VI-Pu-8-2024-801(1)-2023: rules 40 to 56, 65, 66 and 72, Schedules VI and VII, Forms A-4, A-8 and A-11 to A-13 (opens in a new tab)checked 25 October 2026
  27. Home Department, Government of Odisha: Order No. 50908 of 19 November 2019: procedure for issue and renewal of Fire Safety Certificates and Fire Safety Recommendations (issuing officer, validity, inspecting team and time limit by building type) (opens in a new tab)checked 25 October 2026
  28. Delhi Fire Service: Delhi Fire Service Rules, 2010 (consolidated copy) (opens in a new tab)checked 25 October 2026
  29. Government of Maharashtra (gazette copy hosted by Maharashtra Fire and Emergency Services): Maharashtra Fire Prevention and Life Safety Measures Act, 2006, English gazette of 5 February 2007 (sections 3, 8, 36 to 38 read off the page images) (opens in a new tab)checked 25 October 2026
  30. Local Self Government Department, Government of Kerala (Kerala Gazette copies): Kerala Municipality Building Rules, 2019 (G.O.(P) No.77/2019/LSGD, S.R.O. No.828/2019, 8 November 2019) with the Amendment Rules, 2020 (G.O.(P) No.57/2020/LSGD, S.R.O. No.639/2020): rule 5(4) items 12 and 13, rules 28, 29, 35, 80 and 81, Appendix L (opens in a new tab)checked 25 October 2026
  31. Government of Goa, Official Gazette Series I No. 36 (Extraordinary), 9 December 2025 (PRS Legislative Research copy): The Goa Jan Vishwas (Laws Amendment) Ordinance, 2025 (Ordinance No. 4 of 2025), promulgated 2 December 2025: Schedule I item 3 amends sections 20 and 21 of the Goa Fire Force Act, 1986 (opens in a new tab)checked 24 October 2026
  32. Delhi Development Authority: Unified Building Bye-Laws for Delhi 2016, compendium incorporating amendments up to 12 February 2020: clause 7.11 staircases (1.5 m for guest houses) and Annexure V (Rule 27, 2010 text) (opens in a new tab)checked 25 October 2026
  33. Department of Information and Public Relations, UT Ladakh: Ladakh Administration initiates revision of Building Bye-Laws, 2024 (press release, Leh, 16 October 2025): proposed fire NOC exemptions and OBPS (opens in a new tab)checked 24 October 2026
  34. Home Department, Government of Odisha: Odisha Fire Prevention and Fire Safety (Amendment) Rules, 2019, notification No. 10573/H of 6 March 2019: rule 9(1) classes, rules 10, 13(3) and 22(5) (opens in a new tab)checked 24 October 2026
  35. Delhi Fire Service: Department of Delhi Fire Service, Govt of NCT of Delhi (home page and portal links) (opens in a new tab)checked 25 October 2026
  36. Kerala Fire and Rescue Services: NOC portal home: live application counters, trial-run banner, A1 fire-plan notice and complaint address (opens in a new tab)checked 24 October 2026
  37. Home Department, Chhattisgarh (on the CG Fire NOC portal): Notification under section 14(1), 29 November 2022: buildings that need a fire NOC (opens in a new tab)checked 24 October 2026
  38. Government of Manipur (PRS copy): Manipur Fire and Emergency Service Act, 2026 (Act 9 of 2026) (opens in a new tab)checked 24 October 2026
  39. Directorate of Fire and Emergency Services, Nagaland: Nagaland Fire and Emergency Services Act (Act No. 5 of 2023), Nagaland Gazette, 31 August 2023 (opens in a new tab)checked 24 October 2026
  40. Home Department, Government of Mizoram (copy on the Mizoram Fire and Emergency Services site): Notification No. B-20011/2/2026-HM(F&ES), 20 August 2026: Mizoram Fire and Emergency Services (Superintendence and Control of the Fire Force and Fire Safety and Prevention) (Amendment) Rules, 2026, substituting Rule 57 and inserting Rules 57(A) and 57(B) (opens in a new tab)checked 25 October 2026
  41. Urban Development Department, Rajasthan: Model Rajasthan Building Regulations, 2025, order No. P-11(5)/UDH/Bhavan Viniyam-2025/2025 (listed 12 May 2025): Regs 2.36, 2.75, 2.77, 4.6.2, 5.4, 11.2, 14.5 and Schedules 2 and 3 (opens in a new tab)checked 25 October 2026
  42. Casemine (secondary copy of the Act text): Delhi Fire Service Act, 2007: sections 29, 31, 37, 44, 49, 52 and 54 (opens in a new tab)Peer-reviewed study · checked 24 October 2026
  43. CaseMine (legal database): Karnataka Fire Force Act, 1964: sections 24 and 25 (opens in a new tab)Peer-reviewed study · checked 24 October 2026
  44. The Week (PTI), 30 June 2025: Delhi govt withdraws regulations on swimming pools, hotels and other commercial activities: no Delhi Police licence for hotels, motels and guest houses (opens in a new tab)News report · checked 25 October 2026
  45. The Goan: Hundreds of shacks, hotels operate without fire NOCs (16 January 2026): fire NOC figures tabled in the Goa Assembly (opens in a new tab)News report · checked 24 October 2026
  46. India TV (IANS), 27 May 2019: Delhi government notifies building bylaws for fire safety: guest houses above four floors, CO detectors, no rooftop cooking (opens in a new tab)News report · checked 25 October 2026
  47. The Quint (IANS), 27 February 2019: Over 150 Delhi guest houses shut for violating fire safety norms (opens in a new tab)News report · checked 25 October 2026
  48. UNI: Malviya Nagar fire: Delhi Revenue Department inspects guest houses, hotels, restaurants; notices served to 72 violating norms (opens in a new tab)News report · checked 24 October 2026